Part 1: Functional specification
8 Conformance
8.1 Introduction
8.1.1 Table of contents
Table 8.1 contains the table of contents for this clause.
Table 8.1 — Table of contents
8.1.2 Overview
This clause specifies conformance of:
- functional implementations of SEDRIS,
- SEDRIS transmittals,
- exchange formats that use DRM data structures and associated data types,
- applications that read and/or write transmittals represented in these exchange formats,
- language bindings of the SEDRIS application program interface, and
- applications that use the SEDRIS application program interface.
The concept of profile conformance is specified to ensure
interoperability of SEDRIS-capable applications that generate or use SEDRIS
transmittals. The Default Profile requires support for all DRM classes, API
functions, and data types specified in this part of ISO/IEC 18023 (see 8.3.2 Default Profile).
8.2 General Conformance
8.2.1 Functional conformance
An implementation of the
concepts and the application program interface described in this International
Standard shall be conformant, if the following conditions are satisfied:
- The implementation shall support the data types specified in
5 Fundamental data types. Additional
internal data types may be used by an implementation, but such data types shall
not be used in the interfaces of DRM classes as specified in
6 DRM classes, as
parameters to any API function specified in
7 Application program interface (API), or within SEDRIS
transmittals.
- The implementation shall support DRM classes as specified in
6 DRM classes.
An implementation shall generate an API error message for any DRM class that is
not specified in 6 DRM classes but is encountered in a transmittal.
- The implementation shall support relationships between instances of DRM
classes only as specified in this International Standard.
- The implementation shall support the functions specified in 7 Application program interface (API).
While other functions may be provided by an implementation, they shall not be
used to directly access the data in a transmittal.
- The implementation shall support access (read and write as appropriate)
to SEDRIS transmittals stored in the encoding specified in
Part 3 of ISO/IEC 18023.
- All entities supported shall match the functional specification of the
corresponding entities of this part of ISO/IEC 18023.
The data identified by URNs in the <DRM Sound>, <DRM Browse Media>, and <DRM_Symbol> classes need not be
interpretable by an implementation for that implementation to be conformant.
8.2.2 Conformance of SEDRIS transmittals
A SEDRIS transmittal shall be conformant to this part of
ISO/IEC 18023 if it satisfies the following criteria:
- All entities in the transmittal shall obey the constraints, rules, and
connectivity established in this part of ISO/IEC 18023;
- No data is introduced other than that allowed by this part of ISO/IEC
18023 or specifically provided by the encoding specification for the
transmittal format;
- No entities are included that are not also specified to be part of the
applicable profile; and
- All entities are accessible using only an implementation of the SEDRIS API.
8.2.3 Conformance of encodings for SEDRIS transmittals
An encoding shall be conformant to this part of
ISO/IEC 18023 if it satisfies the following criteria:
- The entities of the encoding shall precisely match the functional
specification of the corresponding data types, DRM class instances, and
relationships specified in this part of ISO/IEC 18023;
- The encoding shall impose no restrictions on the data
representations that are not already specified in this part of ISO/IEC 18023;
and
- The encoding shall be capable of identifying the profile of SEDRIS that
is represented in the encoded transmittal.
8.2.4 Conformance of applications that read and/or write SEDRIS
transmittals represented in these encodings
An application that uses the encodings for
transmittals shall be considered conformant to this part of ISO/IEC 18023 if it
satisfies the following criteria:
- the constructs specified in this part of ISO/IEC 18023 are used only as specified
herein; and
- only the relationships allowed in this part of ISO/IEC 18023 are
generated.
8.2.5 Conformance of language bindings of the
application program interface
A language binding of the SEDRIS API to a programming language shall be conformant if
the following conditions are satisfied:
- all functions specified in this part of ISO/IEC 18023 are bound so as to
present the specified interfaces as closely as possible given the strictures of
that programming language;
- all data types specified in this part of ISO/IEC 18023 can be represented
in that programming language; and
- the resulting language binding obeys the cultural aspects of that programming language.
8.2.6 Conformance of applications that use the
application program interface
An application that uses the API shall be conformant if the following conditions are satisfied:
- Only the API functions that are specified in this part of ISO/IEC 18023
are used to provide access to SEDRIS transmittals, and
- All error messages received from the API are processed as required by
this part of ISO/IEC 18023.
It is not necessary for an application to be able to interpret the data identified by the
URNs of <DRM Sound>, <DRM Browse Media>, and <DRM_Symbol> to be considered conformant.
8.3 Minimum implementation criteria
8.3.1 Basic properties
The concept of profiles is specified in
4.20 Profiles. This part of ISO/IEC 18023 specifies the Default Profile
(see 8.3.2 Default Profile). Other profiles may
only be developed by amending this part of ISO/IEC 18023.
8.3.2 Default Profile
Conformance to the Default Profile shall include support for:
- all DRM classes specified in this part of ISO/IEC 18023,
- all API functions and their behaviours specified in this part of ISO/IEC 18023, and
- all data types specified in this part of ISO/IEC 18023.
An implementation conforming to the Default Profile shall
support the functional and operational concepts and capabilities specified in
4 Concepts.
In addition, the Default Profile
shall be able to support transmittals without introducing any
restrictions as to size or complexity except as specified in this part of
ISO/IEC 18023.
http://www.iso.ch/iso/en/ittf/PubliclyAvailableStandards/ISO_IEC_18023-1_Ed1.html